An ECT report consists of three sections - a summary report, a graphical
format, and a tabular report. The summary report provides an overall one
page executive summary of the inspection. The graphical report is a map
of the heat exchanger tubesheet with defects shown in colors
representing five different defect depth ranges. The tabular format
presents the results of the inspection in each tube, including the
row number, tube number, defect depth, defect side (ID/OD) and
remaining wall. Click below for example of ECT Report Section A: Summary Report Section B: Graphical Report Section C: Tabular Report Additional Information: ECT Signals
|
|
|
|
NDE Associates, Inc. |
||