DETECTING TUBE DEFECTS WITH HIGH RELIABILITY

NDE Associates, Inc. provides eddy current testing services for heat exchanger tubing. Heat exchanger tube inspections in petrochemical plants and power plants are done to detect various kinds of defects including ID and OD pitting, cracking and SCC, Microbial Induced Corrosion (MIC) damage, support wear, cracking in the tubesheet expansion roll, wear, erosion, etc. NDE Associates, Inc. inspectors are also trained in noticing the differences between defects and signals from metallic deposits.

A/C Chiller tubing that is typically copper, copper-nickel and brass is inspected for cracking, pitting, wear and freeze bulges. See A/C chiller tube inspection Rates.

 

Case Studies

Crack at tube support. Inconel tube 3/4 inch OD x 0.049 inch t. Crack is axial with a length was 0.06 inch.

Metallograph showing OD initiated SCC. Crack detected in the mix channel.

 